Legacy Line™ Puron Advance™ Single-Packaged Rooftop Units with Axion™ Technology
Gas Heating / Electric Cooling 3 to 27.5 Nominal Tons
Bryant’s Legacy Line™ rooftops (RTU) with Puron Advance™ (R-454B) and Axion™ Fan Technology, offer an environmentally sustainable for a brighter future. With a GWP of 466 and similar performance to R-410A, Puron Advance easily exceeds the EPA's new, stringent, <700 GWP refrigerant requirement. Our direct drive Axion™ indoor fan system uses a Vane Axial fan and electronically commutated motor. The benefit is clear: when compared to legacy belt drive systems, this Vane Axial design has 75% fewer moving parts, uses up to 40% less energy, and has no belts, blower bearings, or shaft. Our Legacy Line™ 582L/559L units are designed to be a direct replacement for many existing rooftops. That makes replacements fast and easy, eliminating the need for curb adapters or different utility connections.
Product Certifications: AHRI, UL
- SEER Rating :
- 13.4 SEER2
FEATURES
Performance Features
- Puron Advance (R-454B) refrigerant meets and exceeds EPA’s new Low GWP requirements
- New – UL 60335-2-40 Certified A2L leak detection and dissipation system factory installed standard
- Direct Drive Axion™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
- Single-stage cooling capacity 04-06 models, two-stage on 07+ models
- New Unit Control Board with intuitive quick fan speed adjustment
- SEER2s up to 13.4, IEER up to 15.5
- Gas efficiencies up to 81%
- Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Exclusive IGC solid-state control for on-board diagnostics with LED error code designation and burner control logic
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
- Units meet ASHRAE 90.1 energy efficiency levels.
Maintenance Features
- New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
- Access panels with easy grip handles
- Innovative, easy starting, no-strip screw feature on unit access panels
- Tool-less filter access door
- Optional hinged access panels also available
- NEW Direct Drive – Axion™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
- Two-inch disposable return air filters
Installation Features
- Same footprint as prior Bryant models for that original fit; reduces installation costs and time
- Field convertible from vertical to horizontal airflow configuration on units up to 15 tons
- Provisions for thru-the-bottom power entry capability as standard
- Single point gas, electric, and controls connections
- Full perimeter base rail with built-in rigging adapters and fork truck slots
Reliability Features
- A2L leak detection and dissipation system standard
- Scroll compressors with internal line-break overload protection
- 24-volt control circuit protected with resettable circuit breaker
- Permanently lubricated direct-drive ECM evaporator-fan motor
- Totally enclosed condenser motors with permanently lubricated bearings
- Low pressure and high-pressure switch protection
- Exclusive IGC anti-cycle protection for gas heat operation
- Solid-state electronic direct spark ignition system and flame roll-out safety protector
Standard Limited Warranty
- 10 years parts only heat exchanger - aluminized
- 15 years parts only heat exchanger - stainless steel
- 10 years parts only heat exchanger – Ultra/Low NOx models
- 5 years parts only compressor
- One-year parts only on all other parts
- Additional extended warranty packages available
SPECIFICATIONS
Factory-Installed Options
- Temperature Sensing Economizer with relief
- Enthalpy Sensing Economizer with relief
- Perfect Humidity™ Adaptive Dehumidification System
- Multiple Gas Heat Sizes
- Stainless Steel Gas Heat Exchangers
- Return Air Smoke Detector
- Supply Air Smoke Detector
- CO2 Sensor
- Condensate Overflow Protection
- Multiple Static Fan Capabilities
- Thru-The-Base Utility Connections
- Louvered Hail Guards
- Non-Fused Disconnect Switch
- Hinged Access Panels
- Unpowered Convenience Outlet
- Powered Convenience Outlet
- Coated Coils:
- Pre-Coat
- E-Coat
- Copper/Copper
- Electrical Mechanical Controls
- Extended Warranty Protection Plans
Performance Features
- Puron Advance (R-454B) refrigerant meets and exceeds EPA’s new Low GWP requirements
- New – UL 60335-2-40 Certified A2L leak detection and dissipation system factory installed standard
- Direct Drive Axion™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
- Single-stage cooling capacity 04-06 models, two-stage on 07+ models
- New Unit Control Board with intuitive quick fan speed adjustment
- SEER2s up to 13.4, IEER up to 15.5
- Gas efficiencies up to 81%
- Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Exclusive IGC solid-state control for on-board diagnostics with LED error code designation and burner control logic
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
- Units meet ASHRAE 90.1 energy efficiency levels.
Maintenance Features
- New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
- Access panels with easy grip handles
- Innovative, easy starting, no-strip screw feature on unit access panels
- Tool-less filter access door
- Optional hinged access panels also available
- NEW Direct Drive – Axion™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
- Two-inch disposable return air filters
Installation Features
- Same footprint as prior Bryant models for that original fit; reduces installation costs and time
- Field convertible from vertical to horizontal airflow configuration on units up to 15 tons
- Provisions for thru-the-bottom power entry capability as standard
- Single point gas, electric, and controls connections
- Full perimeter base rail with built-in rigging adapters and fork truck slots
Reliability Features
- A2L leak detection and dissipation system standard
- Scroll compressors with internal line-break overload protection
- 24-volt control circuit protected with resettable circuit breaker
- Permanently lubricated direct-drive ECM evaporator-fan motor
- Totally enclosed condenser motors with permanently lubricated bearings
- Low pressure and high-pressure switch protection
- Exclusive IGC anti-cycle protection for gas heat operation
- Solid-state electronic direct spark ignition system and flame roll-out safety protector
Standard Limited Warranty
- 10 years parts only heat exchanger - aluminized
- 15 years parts only heat exchanger - stainless steel
- 10 years parts only heat exchanger – Ultra/Low NOx models
- 5 years parts only compressor
- One-year parts only on all other parts
- Additional extended warranty packages available
Factory-Installed Options
- Temperature Sensing Economizer with relief
- Enthalpy Sensing Economizer with relief
- Perfect Humidity™ Adaptive Dehumidification System
- Multiple Gas Heat Sizes
- Stainless Steel Gas Heat Exchangers
- Return Air Smoke Detector
- Supply Air Smoke Detector
- CO2 Sensor
- Condensate Overflow Protection
- Multiple Static Fan Capabilities
- Thru-The-Base Utility Connections
- Louvered Hail Guards
- Non-Fused Disconnect Switch
- Hinged Access Panels
- Unpowered Convenience Outlet
- Powered Convenience Outlet
- Coated Coils:
- Pre-Coat
- E-Coat
- Copper/Copper
- Electrical Mechanical Controls
- Extended Warranty Protection Plans
Documents
California residents please see Proposition 65
PHYSICAL DATA
Gas Heating/Electric Cooling Models (582L)
| Nominal Cooling Ton Size | Cooling Stages | AHRI Efficiency (SEER) IEER | Dimension (in) LxWxH | Low Gas Heating Input (Btuh) | Medium Gas Heating Input (Btuh) | High Gas Heating Input (Btuh) | Approx. Unit Weight (lbs) |
|---|---|---|---|---|---|---|---|
| 3.0 | 1 | (13.4) | 74 x 47 x 33 | 67 | 110 | -- | 482 |
| 4.0 | 1 | (13.4) | 74 x 47 x 33 | 67 | 110 | 150 | 543 |
| 5.0 | 1 | (13.4) | 74 x 47 x 33 | 67 | 110 | 150 | 566 |
| 6.0 | 2 | 15.5 | 74 x 47 x 41 | 67 | 110 | 150 | 607 |
| 7.5 | 2 | 15.0 | 88 x 59 x 41 | 125 | 180 | 224 | 787 |
| 8.5 | 2 | 15.0 | 88 x 59 x 49 | 125 | 180 | 224 | 868 |
| 10.0 | 2 | 15.0 | 88 x 59 x 49 | 180 | 224 | 250 | 878 |
| 12.5 | 2 | 15.0 | 88 x 59 x 49 | 180 | 224 | 250 | 1041 |
| 15.0 | 2 | 14.5 | 115 x 63 x 57 | 180 | 240 | 350 | 1408 |
| 17.5 | 2 | 14.5 | 127 x 86 x 49 | 220 | 310 | 400 | 1800 |
| 20.0 | 2 | 14.5 | 141 x 86 x 49 | 220 | 310 | 400 | 2000 |
| 25.0 | 2 | 14.0 | 141 x 86 x 57 | 220 | 310 | 400 | 2174 |
| 27.5 | 2 | 14.0 | 157 x 86 x 57 | 220 | 310 | 400 | 2351 |
AHRI = Air-Conditioning, Heating and Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER2 = Seasonal Energy Efficiency Ratio 2
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER2 = Seasonal Energy Efficiency Ratio 2
NOTES
- Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6+ ton
- Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.
- 582L units comply with ASHRAE 90.1 Energy Standard. Please review size specific data for compliance
- 582L units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap-energy.org