Skip to main content

Legacy Line™ Puron Advance™ Single-Packaged Rooftop Units with Axion™ Technology

Gas Heating / Electric Cooling 3 to 27.5 Nominal Tons

Bryant’s Legacy Line™ rooftops (RTU) with Puron Advance™ (R-454B) and Axion™ Fan Technology, offer an environmentally sustainable for a brighter future. With a GWP of 466 and similar performance to R-410A, Puron Advance easily exceeds the EPA's new, stringent, <700 GWP refrigerant requirement. Our direct drive Axion™ indoor fan system uses a Vane Axial fan and electronically commutated motor. The benefit is clear: when compared to legacy belt drive systems, this Vane Axial design has 75% fewer moving parts, uses up to 40% less energy, and has no belts, blower bearings, or shaft. Our Legacy Line™ 582L/559L units are designed to be a direct replacement for many existing rooftops. That makes replacements fast and easy, eliminating the need for curb adapters or different utility connections.

Product Certifications: AHRI, UL

SEER Rating :
13.4 SEER2
FEATURES

Performance Features

  • Puron Advance (R-454B) refrigerant meets and exceeds EPA’s new Low GWP requirements
  • New – UL 60335-2-40 Certified A2L leak detection and dissipation system factory installed standard
  • Direct Drive Axion™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
  • Single-stage cooling capacity 04-06 models, two-stage on 07+ models
  • New Unit Control Board with intuitive quick fan speed adjustment
  • SEER2s up to 13.4, IEER up to 15.5
  • Gas efficiencies up to 81%
  • Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
  • Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Exclusive IGC solid-state control for on-board diagnostics with LED error code designation and burner control logic
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
  • Units meet ASHRAE 90.1 energy efficiency levels.

Maintenance Features

  • New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • NEW Direct Drive – Axion™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as prior Bryant models for that original fit; reduces installation costs and time
  • Field convertible from vertical to horizontal airflow configuration on units up to 15 tons
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point gas, electric, and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • A2L leak detection and dissipation system standard
  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated direct-drive ECM evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Exclusive IGC anti-cycle protection for gas heat operation
  • Solid-state electronic direct spark ignition system and flame roll-out safety protector

Standard Limited Warranty

  • 10 years parts only heat exchanger - aluminized
  • 15 years parts only heat exchanger - stainless steel
  • 10 years parts only heat exchanger – Ultra/Low NOx models
  • 5 years parts only compressor
  • One-year parts only on all other parts
  • Additional extended warranty packages available
SPECIFICATIONS

Factory-Installed Options

  • Temperature Sensing Economizer with relief
  • Enthalpy Sensing Economizer with relief
  • Perfect Humidity™ Adaptive Dehumidification System
  • Multiple Gas Heat Sizes
  • Stainless Steel Gas Heat Exchangers
  • Return Air Smoke Detector
  • Supply Air Smoke Detector
  • CO2 Sensor
  • Condensate Overflow Protection
  • Multiple Static Fan Capabilities
  • Thru-The-Base Utility Connections
  • Louvered Hail Guards
  • Non-Fused Disconnect Switch
  • Hinged Access Panels
  • Unpowered Convenience Outlet
  • Powered Convenience Outlet
  • Coated Coils:
    • Pre-Coat
    • E-Coat
    • Copper/Copper
  • Electrical Mechanical Controls
  • Extended Warranty Protection Plans

Performance Features

  • Puron Advance (R-454B) refrigerant meets and exceeds EPA’s new Low GWP requirements
  • New – UL 60335-2-40 Certified A2L leak detection and dissipation system factory installed standard
  • Direct Drive Axion™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
  • Single-stage cooling capacity 04-06 models, two-stage on 07+ models
  • New Unit Control Board with intuitive quick fan speed adjustment
  • SEER2s up to 13.4, IEER up to 15.5
  • Gas efficiencies up to 81%
  • Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
  • Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Exclusive IGC solid-state control for on-board diagnostics with LED error code designation and burner control logic
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
  • Units meet ASHRAE 90.1 energy efficiency levels.

Maintenance Features

  • New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • NEW Direct Drive – Axion™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as prior Bryant models for that original fit; reduces installation costs and time
  • Field convertible from vertical to horizontal airflow configuration on units up to 15 tons
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point gas, electric, and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • A2L leak detection and dissipation system standard
  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated direct-drive ECM evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Exclusive IGC anti-cycle protection for gas heat operation
  • Solid-state electronic direct spark ignition system and flame roll-out safety protector

Standard Limited Warranty

  • 10 years parts only heat exchanger - aluminized
  • 15 years parts only heat exchanger - stainless steel
  • 10 years parts only heat exchanger – Ultra/Low NOx models
  • 5 years parts only compressor
  • One-year parts only on all other parts
  • Additional extended warranty packages available

Factory-Installed Options

  • Temperature Sensing Economizer with relief
  • Enthalpy Sensing Economizer with relief
  • Perfect Humidity™ Adaptive Dehumidification System
  • Multiple Gas Heat Sizes
  • Stainless Steel Gas Heat Exchangers
  • Return Air Smoke Detector
  • Supply Air Smoke Detector
  • CO2 Sensor
  • Condensate Overflow Protection
  • Multiple Static Fan Capabilities
  • Thru-The-Base Utility Connections
  • Louvered Hail Guards
  • Non-Fused Disconnect Switch
  • Hinged Access Panels
  • Unpowered Convenience Outlet
  • Powered Convenience Outlet
  • Coated Coils:
    • Pre-Coat
    • E-Coat
    • Copper/Copper
  • Electrical Mechanical Controls
  • Extended Warranty Protection Plans
Documents

California residents please see Proposition 65

PHYSICAL DATA
Gas Heating/Electric Cooling Models (582L)
Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) IEER Dimension (in) LxWxH Low Gas Heating Input (Btuh) Medium Gas Heating Input (Btuh) High Gas Heating Input (Btuh) Approx. Unit Weight (lbs)
3.0 1 (13.4) 74 x 47 x 33 67 110 -- 482
4.0 1 (13.4) 74 x 47 x 33 67 110 150 543
5.0 1 (13.4) 74 x 47 x 33 67 110 150 566
6.0 2 15.5 74 x 47 x 41 67 110 150 607
7.5 2 15.0 88 x 59 x 41 125 180 224 787
8.5 2 15.0 88 x 59 x 49 125 180 224 868
10.0 2 15.0 88 x 59 x 49 180 224 250 878
12.5 2 15.0 88 x 59 x 49 180 224 250 1041
15.0 2 14.5 115 x 63 x 57 180 240 350 1408
17.5 2 14.5 127 x 86 x 49 220 310 400 1800
20.0 2 14.5 141 x 86 x 49 220 310 400 2000
25.0 2 14.0 141 x 86 x 57 220 310 400 2174
27.5 2 14.0 157 x 86 x 57 220 310 400 2351


AHRI = Air-Conditioning, Heating and Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER2 = Seasonal Energy Efficiency Ratio 2

NOTES

  1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6+ ton
  2. Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.
  3. 582L units comply with ASHRAE 90.1 Energy Standard. Please review size specific data for compliance
  4. 582L units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap-energy.org