Legacy Line™ Puron Advance™ Single-Packaged Rooftop Units with Axion™ Technology
ECONOMIC CHOICES FOR COMMERCIAL BUILDING APPLICATIONS
Bryant’s Legacy Line™ rooftops (RTU) with Puron Advance™ (R-454B) and Axion™ Fan Technology, offer an environmentally sustainable for a brighter future. With a GWP of 466 and similar performance to R-410A, Puron Advance easily exceeds the EPA's new, stringent, <700 GWP refrigerant requirement. Our direct drive Axion™ indoor fan system uses a Vane Axial fan and electronically commutated motor. The benefit is clear: when compared to legacy belt drive systems, this Vane Axial design has 75% fewer moving parts, uses up to 40% less energy, and has no belts, blower bearings, or shaft.
- SEER Rating :
- 13.4 SEER2
Features
- Puron Advance (R-454B) refrigerant meets and exceeds EPA’s new Low GWP requirements
- New – UL 60335-2-40 Certified A2L leak detection and dissipation system factory installed standard
- Direct Drive Axion™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
- Single-stage cooling capacity 04-06 models, two-stage on 07+ models
- New Unit Control Board with intuitive quick fan speed adjustment
- SEER2s up to 13.4, IEER up to 15.5
- Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
- Units meet ASHRAE 90.1 energy efficiency levels.
Specifications
PERFORMANCE
Efficiency Efficiency Up to 13.4 SEER2 / Up to 15.5 IEER
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.
- Puron Advance (R-454B) refrigerant meets and exceeds EPA’s new Low GWP requirements
- New – UL 60335-2-40 Certified A2L leak detection and dissipation system factory installed standard
- Direct Drive Axion™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
- Single-stage cooling capacity 04-06 models, two-stage on 07+ models
- New Unit Control Board with intuitive quick fan speed adjustment
- SEER2s up to 13.4, IEER up to 15.5
- Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
- Units meet ASHRAE 90.1 energy efficiency levels.
PERFORMANCE
Efficiency Efficiency Up to 13.4 SEER2 / Up to 15.5 IEER
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.
Documents