Skip to main content

Evolution™ Split System Geothermal Heat Pump

GZ

A Preferred Match with Your High Efficiency Furnace or Fan Coil

The Bryant® GZ model offers high-efficiency geothermal cooling performance and is designed to be coupled with a gas/propane furnace or fan coil. It features a quiet, two-stage scroll compressor and, in the right combination, can allow you to enjoy the benefits of Hybrid Heat® technology to gain efficient geothermal heating before switching over to gas in colder weather.
EER Efficiency Range :
15.4 to 28.8 EER (closed loop); 19.2 to 30.5 EER (open loop)
COP Efficiency Range :
3.4 to 4.6 COP (closed loop); 3.9 to 5.1 COP (open loop)
Compressor Type :
Two-Stage Scroll

2 out of 5 star
5
0
4
0
3
0
2
1
1
0
Features
  • Manage your utility costs with high-efficiency comfort (efficiency is unit size dependent):   Closed loop cooling EER - Up to 28.8;  Closed loop heating COP - Up to 4.6
  • Two-stage scroll compressor operation allows longer, more consistent cycles in lower stage for savings and comfort 
  • Optimal dehumidification capability with the Evolution Connex™ control
  • Insulated cabinet and compressor blanket for quiet operation
  • Wide operating temperature range with exceptional cold weather performance
  • Compatible with a wide range of furnaces and fan coils
  • 10-year parts and labor limited warranty1
OPTIONAL FEATURES
  • Supplemental, domestic hot water generation
 
1. To the original owner, when installed in a residence, a 10-year parts and labor limited warranty upon timely registration of equipment. Warranty period is 10 years on parts and 5 years on labor if not registered within 90 days of installation. Original owners residing in jurisdictions that prohibit warranty benefits conditioned on registration will automatically receive a 10-year parts and labor limited warranty. See warranty certificate for  details. 
Specifications

EFFICIENCY MANAGEMENT 

Cooling Efficiency 15.4 to 28.8 EER (closed loop); 19.2 to 30.5 EER (open loop)
Heating Efficiency 3.4 to 4.6 COP (closed loop); 3.9 to 5.1 COP (open loop)
Heating and Cooling Stages Two-stage operation for efficiency and comfort
Hybrid Heat® System Capable Allows gas furnace/heat pump system combination use for heating season
ENERGY STAR® ENERGY STAR® qualified in all sizess (6-ton size only qualifies when paired with a properly sized evaporator coil)

SOUND

Quiet Levels Quiet operation enhanced by full cabinet insulation; double-isolation compressor mounting and compressor sound blanket

CONVENIENCES

Maintenance Reminders With Evolution Connex control

TECHNOLOGY

Blower Motor Dependent on furnace or fan coil paired with
Compressor Two-stage scroll
Control Board Microprocessor with compressor diagnostic capability
Refrigerant Puron® refrigerant
Refrigerant Management Thermostatic expansion valve

INSTALLATION

Placement Indoor

AESTHETICS

Capacity 2-6 tons
Construction Galvanized steel
Paint Baked-on urethane base coat and polyester top coat
 
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.
  • Manage your utility costs with high-efficiency comfort (efficiency is unit size dependent):   Closed loop cooling EER - Up to 28.8;  Closed loop heating COP - Up to 4.6
  • Two-stage scroll compressor operation allows longer, more consistent cycles in lower stage for savings and comfort 
  • Optimal dehumidification capability with the Evolution Connex™ control
  • Insulated cabinet and compressor blanket for quiet operation
  • Wide operating temperature range with exceptional cold weather performance
  • Compatible with a wide range of furnaces and fan coils
  • 10-year parts and labor limited warranty1
OPTIONAL FEATURES
  • Supplemental, domestic hot water generation
 
1. To the original owner, when installed in a residence, a 10-year parts and labor limited warranty upon timely registration of equipment. Warranty period is 10 years on parts and 5 years on labor if not registered within 90 days of installation. Original owners residing in jurisdictions that prohibit warranty benefits conditioned on registration will automatically receive a 10-year parts and labor limited warranty. See warranty certificate for  details. 

EFFICIENCY MANAGEMENT 

Cooling Efficiency 15.4 to 28.8 EER (closed loop); 19.2 to 30.5 EER (open loop)
Heating Efficiency 3.4 to 4.6 COP (closed loop); 3.9 to 5.1 COP (open loop)
Heating and Cooling Stages Two-stage operation for efficiency and comfort
Hybrid Heat® System Capable Allows gas furnace/heat pump system combination use for heating season
ENERGY STAR® ENERGY STAR® qualified in all sizess (6-ton size only qualifies when paired with a properly sized evaporator coil)

SOUND

Quiet Levels Quiet operation enhanced by full cabinet insulation; double-isolation compressor mounting and compressor sound blanket

CONVENIENCES

Maintenance Reminders With Evolution Connex control

TECHNOLOGY

Blower Motor Dependent on furnace or fan coil paired with
Compressor Two-stage scroll
Control Board Microprocessor with compressor diagnostic capability
Refrigerant Puron® refrigerant
Refrigerant Management Thermostatic expansion valve

INSTALLATION

Placement Indoor

AESTHETICS

Capacity 2-6 tons
Construction Galvanized steel
Paint Baked-on urethane base coat and polyester top coat
 
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.
Documents
Chat-Icon